Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.031
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
BMJ Case Rep ; 17(5)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740444

RESUMO

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Assuntos
Neoplasias Laríngeas , Laringectomia , Punções , Traqueia , Humanos , Masculino , Laringectomia/métodos , Laringectomia/efeitos adversos , Neoplasias Laríngeas/cirurgia , Punções/métodos , Traqueia/cirurgia , Esôfago/cirurgia , Grampeadores Cirúrgicos , Idoso , Pessoa de Meia-Idade , Laringe/cirurgia , Grampeamento Cirúrgico/métodos , Laringe Artificial
2.
Int J Colorectal Dis ; 39(1): 51, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607585

RESUMO

PURPOSE: Three types of circular staplers can be used to perform a colorectal anastomosis: two-row (MCS), three-row (TRCS) and powered (PCS) devices. The objective of this meta-analysis has been to provide the existing evidence on which of these circular staplers would have a lower risk of presenting a leak (AL) and/or anastomotic bleeding (AB). METHODS: An in-depth search was carried out in the electronic bibliographic databases Embase, PubMed and SCOPUS. Observational studies were included, since randomized clinical trials comparing circular staplers were not found. RESULTS: In the case of AL, seven studies met the inclusion criteria in the PCS group and four in the TRCS group. In the case of AB, only four studies could be included in the analysis in the PCS group. The AL OR reported for PCS was 0.402 (95%-confidence interval (95%-CI): 0.266-0.608) and for AB: 0.2 (95% CI: 0.08-0.52). The OR obtained for AL in TRCS was 0.446 (95%-CI: 0.217 to 0.916). Risk difference for AL in PCS was - 0.06 (95% CI: - 0.07 to - 0.04) and in TRCS was - 0.04 (95%-CI: - 0.08 to - 0.01). Subgroup analysis did not report significant differences between groups. On the other hand, the AB OR obtained for PCS was 0.2 (95% CI: 0.08-0.52). In this case, no significant differences were observed in subgroup analysis. CONCLUSION: PCS presented a significantly lower risk of leakage and anastomotic bleeding while TRCS only demonstrated a risk reduction in AL. Risk difference of AL was superior in the PCS than in TRCS.


Assuntos
Neoplasias Colorretais , Grampeadores Cirúrgicos , Humanos , Anastomose Cirúrgica/métodos
3.
Langenbecks Arch Surg ; 409(1): 145, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38687358

RESUMO

BACKGROUND: A stapler is usually used for transection and closure of the pancreas in distal pancreatectomy (DP) or central pancreatectomy (CP). When the pancreas is transected to the right of the portal vein, it is difficult to use a stapler and clinically relevant postoperative pancreatic fistula (CR-POPF) frequently occurs. We report on the efficacy of pancreaticojejunostomy (PJ) of the pancreatic stump for patients in whom stapler use is difficult. METHODS: Patients who underwent DP or CP were enrolled in this study. The pancreas was usually transected by a stapler, and ultrasonic coagulating shears (UCS) were used depending on the tumor situation. When using UCS, hand-sewn closure or PJ was performed for the pancreatic stump. The relationship between clinicopathological factors and the methods of pancreatic transection and closure were investigated. RESULTS: In total, 164 patients underwent DP or CP, and the pancreas was transected with a stapler in 150 patients and UCS in 14 patients. The rate of CR-POPF was higher and the postoperative hospital stay was longer in the UCS group than in the stapler group. PJ of the pancreatic stump, which was performed for 7 patients, did not worsen intraoperative factors. CR-POPF was not seen in these 7 patients, which was significantly less than that with hand-sewn closure. CONCLUSIONS: PJ of the pancreatic stump during DP or CP reduces CR-POPF compared with hand-sewn closure and may be useful especially when the pancreas is transected to the right of the portal vein.


Assuntos
Pancreatectomia , Fístula Pancreática , Neoplasias Pancreáticas , Pancreaticojejunostomia , Humanos , Pancreaticojejunostomia/métodos , Pancreatectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fístula Pancreática/prevenção & controle , Fístula Pancreática/etiologia , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Adulto , Resultado do Tratamento , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Grampeamento Cirúrgico , Tempo de Internação , Grampeadores Cirúrgicos , Técnicas de Sutura
4.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443753

RESUMO

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de Internação
5.
Colorectal Dis ; 26(4): 766-771, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38302860

RESUMO

AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.


Assuntos
Anastomose Cirúrgica , Colectomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Feminino , Pessoa de Meia-Idade , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Idoso , Masculino , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colectomia/métodos , Colectomia/instrumentação , Colo/cirurgia , Instrumentos Cirúrgicos , Vagina/cirurgia , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Reto/cirurgia , Duração da Cirurgia
6.
World J Surg Oncol ; 22(1): 9, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38172834

RESUMO

BACKGROUND: Automatic staplers are often used to reconstruct the digestive tract during surgeries for gastric cancer. Intragastric free cancer cells adhering to automatic staplers may come in contact with the laparoscopic port area and progress to port site recurrence. This study aimed to investigate the presence/absence of cancer cells adhering to automatic staplers during gastric cancer surgery using cytological examinations. We further determined the positive predictive clinicopathological factors and clinical implications of free cancer cells attached to automatic staplers. METHODS: This study included 101 patients who underwent distal gastrectomy for gastric cancer. Automatic staplers used for anastomosis in gastric cancer surgeries were shaken in 150 ml of saline solution to collect the attached cells. Papanicolaou stains were performed. We tested the correlation between cancer-cell positivity and clinicopathological factors to identify risk factors arising from the presence of attached cancer cells to the staplers. RESULTS: Based on the cytology, cancer cells were detected in 7 of 101 (6.9%) stapler washing fluid samples. Univariate analysis revealed that circular staplers, type 1 tumors, and positive lymph nodes were significantly associated with higher detection of free cancer cells adhering to staplers. No significant differences in other factors were detected. Of the seven cases with positive cytology, one developed anastomotic recurrence. CONCLUSIONS: Exfoliated cancer cells adhered to the automatic staplers used for anastomoses in 6.9% of the staplers used for distal gastrectomies in patients with gastric cancer. Staplers used for gastric cancer surgeries should be handled carefully.


Assuntos
Laparoscopia , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Gastrectomia , Anastomose Cirúrgica , Gastroenterostomia , Grampeadores Cirúrgicos , Estudos Retrospectivos
7.
IEEE Trans Biomed Eng ; 71(1): 97-105, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37440379

RESUMO

OBJECTIVE: This study explores the feasibility of coupling Electrical Impedance Tomography (EIT) to a standard-of-care laparoscopic surgical stapler, stapler+EIT, with the long-term goal of enabling intraoperative tissue differentiation for tumor margin detection. METHODS: Two custom printed-circuit-board-based electrode arrays with 60 and 8 electrodes, respectively, matching the stapler geometry, served as the jaws of an electrode-integrated surrogate stapler+EIT device. The device was evaluated through a series of simulations and bench-top imaging experiments of agar-gel phantoms and bovine tissue samples to evaluate the technique and determine optimal imaging parameters. RESULTS: Electrodes localized to only one jaw (the 60-electrode side) of the stapler outperformed a dual-jaw distribution of electrodes. Using this one-sided electrode array, reconstructions achieved an Area-Under-the-Curve (AUC) ≥ 0.94 for inclusions with conductivity contrasts of ≥30% for any size considered on measured agar-gel tests, and an AUC of 0.80 for bovine tissue samples. CONCLUSION: A stapler+EIT algorithm has been tuned and evaluated on challenging phantom tests and demonstrated to produce accurate reconstructions. SIGNIFICANCE: This work is an important step in the development of a surgical stapler+EIT technique for margin assessment.


Assuntos
Grampeadores Cirúrgicos , Tomografia , Animais , Bovinos , Tomografia/métodos , Impedância Elétrica , Ágar , Tomografia Computadorizada por Raios X , Eletrodos
9.
Ann Ital Chir ; 94: 649-653, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38131379

RESUMO

The suture thread used in digestive surgery must have several characteristics, including resistance to tension until the anastomosis coalescence, rapid absorption to avoid complications, biocompatibility and ease of handling. The preference is for monofilament polymers as they offer greater guarantees in biliary-digestive anastomoses. Suturing with synthetic polymers and mechanical devices such as staplers are the most suitable techniques. It is believed that staplers may become the gold standard technique in robotic surgery based on their experience and experimental data. In general, the goal is to use materials that minimize the risk of post-operative complications and offer maximum reliability in the anastomosis. KEY WORD: Suture material, Stapler.


Assuntos
Polímeros , Grampeadores Cirúrgicos , Humanos , Reprodutibilidade dos Testes , Anastomose Cirúrgica/métodos , Suturas , Técnicas de Sutura
10.
Int J Colorectal Dis ; 38(1): 264, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37932486

RESUMO

PURPOSES: To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA™ circular stapler with Tri-Staple™ technology (three-row) and between Medtronic EEA™ circular stapler with DST™ Series technology (two-row) versus Tri-Staple™ technology. METHODS: A retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019-2022 in U.S. Premier Healthcare Database to assess the risk of AL within 30 days post-index procedure. The study devices were Ethicon manual circular staplers, Medtronic EEA™ circular stapler with DST™ technology, and Medtronic EEA™ circular stapler with Tri-Staple™ technology. RESULTS: Across 447 hospitals, the cumulative incidences (95% confidence intervals [CI]) of AL within 30 days post-index procedure were 7.78% (6.91-8.74%) among 8337 patients in the Ethicon manual circular stapler cohort, 7.54% (6.87-8.27%) among 7928 patients in the Medtronic EEA™ circular stapler with DST™ technology cohort, and 8.19% (6.57-10.07%) among 1306 patients in the Medtronic EEA™ circular stapler with Tri-Staple™ technology cohort. Comparative analyses revealed no difference comparing Ethicon manual circular staplers with Medtronic EEA™ circular staplers with Tri-Staple™ technology (risk ratio [RR], 0.72; 95% CI, 0.52-1.01) or comparing Medtronic EEA™ circular staplers with DST™ technology to Tri-Staple™ technology (RR, 0.75; 95% CI, 0.53-1.06). CONCLUSION: In this analysis of a large cohort of patients undergoing a left-sided colorectal surgery from a U.S. hospital database, the risk of AL observed with manual two-row circular staplers was similar to that seen with three-row devices. This study affirms the safety of manual two-row circular staplers in colorectal anastomosis.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Adulto , Humanos , Fístula Anastomótica/etiologia , Estudos de Coortes , Grampeadores Cirúrgicos/efeitos adversos , Estudos Retrospectivos , Anastomose Cirúrgica/efeitos adversos , Neoplasias Colorretais/cirurgia , Grampeamento Cirúrgico/efeitos adversos
11.
PLoS One ; 18(10): e0287595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37903104

RESUMO

BACKGROUND: Small circular staplers possess the advantage of being relatively easy to use when compared to larger circular staplers. However, there is some contention as to whether the use of small circular staples in colorectal surgery increases the incidence of anastomotic strictures. This study aimed to determine whether the frequency of anastomosis site stricture formation differs depending on stapler size when performing anastomosis in colorectal surgery. METHODS: Patients who underwent surgery for colon or rectal disease between June 1, 2009, and December 31, 2021, and who had circular staplers used for the formation of intestinal anastomoses post colectomy were included in our study. Propensity score matching with a 1:1 ratio using logistic regression was performed. The primary outcome was the anastomotic stricture rate, and the secondary outcome was total anastomotic complications. RESULTS: A total of 875 patients who were operated on by surgeons using 28/29-mm and 25-mm circular staplers were included. After propensity score matching, 106 patients were assigned to each group. Anastomotic strictures occurred in two cases (1.9%) from the 25-mm group and in four cases (3.8%) from the 28/29-mm group. There were no statistically significant differences between the two groups (p = 0.683). Anastomotic complications were observed in two cases (1.9%) from the 25-mm group and in six cases (5.7%) from the 28/29-mm group; no statistically significant differences were found (p = 0.280). CONCLUSION: Circular stapler size does not influence anastomotic stricture formation in colorectal surgery.


Assuntos
Cirurgia Colorretal , Humanos , Constrição Patológica/etiologia , Constrição Patológica/epidemiologia , Pontuação de Propensão , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/etiologia , Estudos Retrospectivos
12.
Int J Colorectal Dis ; 38(1): 211, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37561203

RESUMO

PURPOSE: The aim of the present study is to assess the impact of Echelon Circular™ powered stapler (PCS) on left-sided colorectal anastomotic leaks and to compare results to conventional circular staplers (CCS). METHODS: A single center cohort study was carried out on 552 consecutive patients, who underwent laparoscopic colorectal resection and anastomosis to the rectum between December 2017 and September 2022. Patients who underwent powered circular anastomosis to the rectum were matched to those who had a conventional stapled anastomosis using a propensity score matching. Main outcomes were anastomotic leak (AL) rate, anastomotic bleeding, and postoperative outcomes. RESULTS: After adjusting cases with propensity score matching, two new groups of patients were generated: 145 patients in the PCS and 145 in the CCS. The two groups were homogeneous with respect to demographics and comorbidities on admission. Overall, AL occurred in 21 (7.3%) patients. No significant differences were observed with respect to AL (5.5% in PCS vs 9% in CCS; p = 0.66), fistula severity (p = 0.60) or reoperation rate (p = 0.65) in the two groups in study. A higher rate of anastomotic bleeding was observed in the CCS vs PCS (5.5% vs 0.7%, p = 0.03). At univariate analysis performed after propensity score matching, stapler diameter ≥ 31mm and age ≥ 70 years were the only variable significantly associated with anastomotic leak (p = 0.001 and p = 0.031; respectively). CONCLUSIONS: The powered circular stapler has no impact on AL, while it could affect bleeding rate at the anastomotic site.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Humanos , Idoso , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Reto/cirurgia , Estudos de Coortes , Pontuação de Propensão , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Neoplasias Colorretais/cirurgia , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/métodos
14.
Tech Coloproctol ; 27(12): 1383-1386, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37284973

RESUMO

PURPOSE: Our aim was to develop a Kono-S anastomotic technique using surgical staplers. METHODS: Two patients underwent stapled Kono-S anastomosis, one via abdominal and one transanal approach. RESULTS: The approach for an abdominal and transanal stapled Kono-S anastomosis is detailed. CONCLUSION: The Kono-S anastomosis can be safely configured using common surgical staplers.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/cirurgia , Anastomose Cirúrgica/métodos , Grampeadores Cirúrgicos , Recidiva , Grampeamento Cirúrgico
16.
Surg Innov ; 30(5): 576-585, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37029908

RESUMO

BACKGROUND: Circular stapler anastomosis is a common surgical procedure. Despite technological advancements, anastomotic leak remains a postoperative concern. Assessment of new technologies is impeded by variations in test methods and analysis, precluding outcome reproducibility and direct comparisons of results across studies. The development of robust and reproducible preclinical test methods is critical to accelerating stapling technology advancements. METHODOLOGY: Leak pressure, staple line perfusion and security, and device removal force were quantified for triple-row (Tri-staple EEA, TriEEA) and double-row staplers (Echelon Circular Powered, ECP). Leak and perfusion testing were performed in vivo. Device removal force and staple line security testing were performed with synthetic medium using an Instron. Data were analyzed using unpaired student's t-test or Kruskal-Wallis test, with statistical significance defined as P < .05. RESULTS: Leak pressure was 73% higher in TriEEA vs ECP (P = .016). TriEEA staple line failure force was lower than ECP at 40 and 50 mmHg (P = .001 and P = .023, respectively). Perfusion to the staple line was higher (148%) for TriEEA than for ECP (P = .003) and the force required to remove the device from its stapled anastomosis was 78% lower for TriEEA than for ECP (P < .001). DISCUSSION/CONCLUSIONS: This report addresses a primary limitation in stapling research by presenting novel methodologies which enhance clinical relevance and provide sufficient detail for reproduction by independent investigators. These methods are applied to a comparison between triple-row and double-row staplers to demonstrate utility of new test methods in assessing key technology design features.


Assuntos
Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Grampeamento Cirúrgico/métodos , Reprodutibilidade dos Testes , Fístula Anastomótica/prevenção & controle , Anastomose Cirúrgica/métodos
17.
Am J Surg ; 226(1): 48-52, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36775790

RESUMO

As next generation stapling devices enter the marketplace with robotic adaptations, tri-staple technology, preloaded reinforcement materials, etc., in this perspective piece we assert that a "refresh" in our understanding of the mechanisms of action of these devices is needed. While much attention has been paid to explain the mechanical features of one device versus another, it seems that little to no attention is being paid to understand how an intestinal anastomosis responds biologically to the variations in their use and design. Here we will review various aspects of gastrointestinal stapling in the context of emerging technology in the field and expose the gaps in knowledge that exist regarding the effect of gastrointestinal stapling on the biology of healing.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Grampeamento Cirúrgico , Humanos , Grampeadores Cirúrgicos , Anastomose Cirúrgica , Intestinos
18.
Br J Surg ; 110(9): 1125-1127, 2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-36609641
19.
Dis Esophagus ; 36(5)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-36222069

RESUMO

Anastomotic leakage after esophagectomy is one of the most feared complications, which results in increased morbidity and mortality. Our aim was to evaluate the impact of a powered circular stapler on complications after esophagectomy with intrathoracic anastomosis for esophageal cancer. Between May 2019 and July 2021, all consecutive oesophagectomies for cancer with intrathoracic anastomosis in a high-volume center were included in this retrospective study. Surgeons were free to choose either a manual or a powered circular stapler. Preoperative characteristics and postoperative complications were recorded in a prospective database, according to EsoData. Propensity score matching (age, body mass index, Eastern cooperative oncology group (ECOG) performance and neoadjuvant therapy) was conducted to reduce potential confounding. We included 128 patients. Powered and manual circular staplers were used in 62 and 66 patients, respectively. Fewer anastomotic leakages were observed with the powered stapler group (OR = 7.3 (95%CI: 1.58-33.7); [3.2% (n = 2) vs 19.7% (n = 13), respectively; p = 0.004]). After propensity score matching, this remained statistically significant (OR = 8.5 (95%CI: 1.80-40.1); [4.1% (n = 2) vs 20.4% (n = 10), respectively; p = 0.013]). Additionally, anastomotic diameter was significantly higher with the powered stapler (median: 29 mm (63.3%) vs 25 mm (57.1%), respectively; p < 0.0001). There was no significant difference in comprehensive complication index (p = 0.146). A decreased mean length of stay was observed in the powered stapler group (11.1 vs 18.7 days respectively; p = 0.022). Postoperative anastomotic leakage after esophageal resection was significantly reduced after the introduction of the powered circular stapler, consequently resulting in a reduced length of stay. Further evaluation on long-term strictures and quality of life are warranted to support these results.


Assuntos
Fístula Anastomótica , Neoplasias Esofágicas , Humanos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Pontuação de Propensão
20.
Surg Endosc ; 37(2): 1274-1281, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36175699

RESUMO

BACKGROUND: Staple line reinforcement (SLR) is commonly used in bariatric surgeries to reduce leaks and bleeds. With the evolution of staplers, the need for buttressing with the latest surgical stapling technology is in question. The efficacy of GORE® SEAMGUARD® (G-SLR) to improve staple line strength based on an established measure of burst pressure was evaluated. A benchtop test on synthetic tissue evaluated the pressure required for staple line leak across surgical staplers with and without G-SLR. METHODS: Staple lines on a consistent thickness synthetic bowel were pressurized to the point of failure (burst pressure) among Ethicon®, Intuitive®, and Medtronic® surgical staplers with and without G-SLR. Burst pressure and leak location (through the staple line [TTSL] or through the staple [TTS], on the anvil or cartridge side) were recorded. Visual confirmation of a leak concluded each test. RESULTS: The pooled mean burst pressure for G-SLR was greater (p < 0.05) by 0.494 pounds/square inch compared with no reinforcement with no meaningful differences among staplers. Leak failures were primarily TTS (91.7%) and equally distributed between reinforcement groups with more leak failures on the cartridge side with G-SLR and on the anvil side for non-SLR group. Leaks occurred across the length of staple lines with no discernable pattern. CONCLUSION: Employing a buttressing material strengthens the staple line, as measured by burst pressure, and may reduce the risk for staple line failure. This benchtop study of G-SLR with three commonly used surgical staplers demonstrated a significant increase in burst pressures among the studied stapling devices.


Assuntos
Cirurgia Bariátrica , Laparoscopia , Obesidade Mórbida , Humanos , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Gastrectomia , Suturas , Obesidade Mórbida/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA